Yu, Huifang and Xu, Quanbiao and Zhang, Sanming and Gao, Weijun and Xu, Jianfeng (2017) The Theoretically Studies and Field Testing of Self-Insulation Exterior Wall in the Hot Summer and Cold Winter Zone. Energy and Power Engineering, 09 (10). pp. 654-686. ISSN 1949-243X
EPE_2017092115252936.pdf - Published Version
Download (5MB)
Abstract
The energy efficiency design of the exterior wall in the buildings of the hot summer and cold winter zone of China should consider the heat prevention in summer and the heat insulation in winter. The self-insulation of the exterior wall is a more feasible design to satisfy the energy efficiency of buildings in the zone. However, the systematic research is urgently needed for the self-insulation of the exterior wall in the hot summer and cold winter zone of China. The paper tested the thermal performance of the common non-clay materials such as shale sintered hollow brick, sand autoclaved aerated concrete block, etc. by means of indoor experiments. The energy efficiency effect of the common materials was verified using dynamic calculation soft PKPM and several constitutions of exterior wall with different main bricks and insulation materials on the heat bridge were simulated, too. Besides, the tests of the thermal performance of exterior wall in real constructions were carried out to testify the practical effect of the recommended constitutions of exterior wall with different main bricks and insulation materials on the heat bridge. The conclusions are: the physical and thermal properties of the six non-clay wall material are better than the clay porous brick; the thermal performance of the non-clay brick can be improved obviously through the rational arrangement of the holes; shale sintered hollow brick after increasing the holes and rationalizing the hole arrangement and sand autoclaved aerated concrete block are recommended for buildings in the hot summer and cold winter area of China. The dynamic calculation results show that the thermal performances of the non-clay materials are all satisfied with the energy efficiency; The heat transfer coefficient of the exterior wall with composition ③, in which the main wall was sand autoclaved aerated concrete block and the material on the heat bridge was sand autoclaved aerated concrete plate, is the smallest among the three recommended compositions.
Item Type: | Article |
---|---|
Subjects: | Afro Asian Library > Engineering |
Depositing User: | Unnamed user with email support@afroasianlibrary.com |
Date Deposited: | 15 May 2023 06:12 |
Last Modified: | 21 Sep 2024 04:33 |
URI: | http://classical.academiceprints.com/id/eprint/827 |